Python 2 Garage Door Opener Track Extendion Kit

User Manual: Genie EXCELERATOR EXCELERATOR GENIE GARAGE DOOR OPENER - Manuals and Guides View the owners manual for your GENIE GARAGE DOOR OPENER #EXCELERATOR. Home:Garage Door & Opener Parts:Genie Parts:Genie GARAGE DOOR OPENER Manual

3531835447

_BLI_ Ol COI4TIII<ilT5

Safety Information ...................... 2

Important Installation Instructions ...... 2

Safety Features ......................... 2

Pre-installation Checklist ................ 3

Garage Door Opener Assembly ......... 9

Record Data (for Service) .............. 11

Garage Door Opener Installation ....... 12

Accessories ........................... 22

Maintenance .......................... 25

Troubleshooting ...................... 26

Wiring Diagram ....................... 29

Warranty information .................. 30

Wl' '14 ID4 [ELLICODE,.

For 7' 6" Doors. Extension Kit is available for 8' Doors

Included Wall Control MUST be installed prior to Operation

of this Garage Door Operator.

Safe-T-Beam ® Safety Reverse System Must be Installed and

the Force Controls MUST be Properly Set to dose door.

This Equipment meets or exceeds al Federal, State and UL 325

Safety Requirements.

Will not operate twice as fast on a one-piece door.

_ ! _ _'_%_ _%_ _ %_ 4'__ %_

Garage Doors are heavy objects that move with the help of springs

under high tension and electric opening equipment. Since moving

objects, springs under tension, and electric opening equipment

may cause injuries, your safety and the safety of others depend on

you reading and understanding the information in this manual.

If you have garage door related questions or do not understand the

information presented, call your nearest Genie Factory Authorized

Dealer listed at www.geniecompanyocom, or customer Service at

1-800-35-GENIE..

MOVING DOOR

ELECTRICAL SHOCK

HiGH SPRINGTENSION

EFFECT

WARNING:

Can Cause Serious

Injury or Death

WARNING:

Can Cause Serious

Injury or Death

WARNING:

Can Cause Serious

Injury or Death

Keep people clear of opening while door is moving.

Do Not allow children to play with the door operator.

Do Not operate a door that jams or one that has a broken spring.

Turn off power before removing operator cover.

Whep replacing cover, make sure wires are not pinched or near

mowng parts.

Operator must be properly grounded.

Do Not try to remove, repair or adjust springs or anythinqto

which door sprinq parts are fastened, such as, wood blocks,

steel brackets, caNes or other like items.

Repairs and adjustments must be made by a trained service

person using proper tools and instructions.

WARNING:

TO REDUCETHE RISKOF SEVEREINJURYOR DEATH:

1 READAND FOLLOW ALL SAFETY,INSTALLATIONAND

OPERATIONINSTRUCTIONS.If you have any

questions or do not understand an instruction, call

your service representative.

2 Do Not install operator on an improperly balanced

door. An improperly balanced door could cause

severe injury. Repairs and adjustments to cables,

spring assembly, and other hardware must be made

by a trained service person using proper tools and

instructions.

3Remove all ropes, and disable all locks connected to

the door before installing operator.

4 Install door operator 7 feet or more above the floor.

Mount the emergency release knob 6 feet above

the floor.

5 Do Not connect the operator to the source of power

until instructed to do so.

6 Locate the control button:

• Within sightofdoor.

At a minimum height of 5 feet, so small children

cannot reach it.

Away from all moving parts of the door.

7 Install the entrapment WARNING label next to the

wall button or console. Install the emergency release

tag on, or next to, the emergency release

8 The operator must reverse when the door contacts a

1-1/2 inch his h object on the floor at the center of

the doorway.This is about the size of a 2 x 4 board

laid flat.

Safe-T-Beam ® (STB)Non-Contact Reversing System

Places an invisible beam across door opening, that reverses

the door during down travel to the fully open position if

anything passes through beam.

Safe-T-Reverse ®ContactReversingSystem

Automatically stops and reverses a closing door within 2

seconds of contact with an object.

Safe-T-Stop ®Timed Reversed System

Automatically opens a closing door, if door does not close

within 30 seconds.

Force Guard ® Control

Used to set the force required for opening and closing

door. For maximum safety, set the minimum force required

to fully open and close door.

Automatic Lighting System

Two light bulbs up to 60 Watts max. each, are used for safer

entries and exits.The light turns on when door is activated

and automatically turns off 4.5 minutes later.

Manual Emergency Release

Allows the garage door to be opened or closed manually

for emergencies or maintenance.

?sI-IIe: I'ALL£1 IOH ( HEC, HL SY

This Opener includes parts and supplies needed to install in most garages and

connect to most garage doors. There are many variations of garages and garage

doors. A few additional parts and supplies may be needed to install Opener into

your garage and connect to your garage door. While checking items listed

below, note any additional items you will need.

12'+TapeMeasure • Pencil • Ladder • Level

Che<k l_ollow _s9 .......

C/tICR I}_AJ! C,oH[)I IIOH RH[)

Check condition of vertical stile in center of door, and its connection to door's

top and bottom beams.

AIf door frame is nailed together and not a solid connection, door frame

must be braced or reinforced before installing Opener.

B If door is"lightweight" (made with frame and skin - not so/d),door

(including door frame) must be braced or reinforced before

installing Opener.

CA door opener reinforcement bracket may also be needed to connect

garage door to Opener's Door Bracket. This Opener is designed for

installation on a properly braced sectional door or solidly braced

one-piece door.

DContact your Genie Factory Authorized Dealer or dealer of your garage

door for any necessary bracing and a door opener reinforcement

bracket (if needed) before proceeding.

E If you have a wooden door, measure door's thickness. (1/4" x 2") Lag

Screws are included for installing Door Bracket onto door. If your door

is less than 2"thick, brace door or use shorter Door Bracket Lag

Screws (1/4" x 11/4" - not included)

.& WARNING:

If your door sticks, binds, or is out of

balance, have it adjusted by a Genie Factory

Authorized Dealer. Door springs, cables,

pulleys, brackets and associated hardware

are under extreme tension and can cause

serious injury or death.

NOTE

The Excelerator Opener is equipped with

an automatic Garage Door Balance

Detection System.See Troubleshooting

Guide on page 27.

KEEP FEET CLEAR OF DOOR

_ Sectional Door

Raise door, check alignment and see if it moves freely (Figure 1). If door

appears out of alignment, binds, or does not move smoothly, contact a

Genie Factory Authorized Dealer or dealer of your garage door for repairs

and adjustments to door mechanism.

Raise door to 3' - 4' above ground and carefully let go. Door should stay

stationary. Slight movement is acceptable. More than slight movement

means door is out of balance. Contact a Genie Factory Authorized Dealer

or dealer of your garage door

for repairs and adjustments SECTIONAL DOOR,TORSION SPRINGS

to door mechanism. Springs

Check door type. Make

a note of whether it is a

sectional or a one-piece

door (Figure 2).

J One-Piece Door

Figure 1 Checking door balance

SECTIONAL DOOR, EXTENSION SPRINGS

Stile

ONE-PIECE DOOR, TRACKLESS

Header Area

Figure 2 Note Door Type

G_ _ raGE DOOB M_2 6 4T

Measure garage door height (7'-6", 8'-0", or taller) with

tape measure.

A If door height is 7'-6" or less, continue with Check Step 4.

B If your door height is above 7'-6% make sure your rail is long

enough to open the garage door. If there is any question

contact your Customer Service Representative at

1-800-35-GENIE.

Figure 3 Rail Extension Kit

Rail Extension for

8' door

C4ECH DOOB _S_C}_}_ ABEA

NOTE

The header is a heavily reinforced section of the wall just

above the top of the garage door opening.

A Find vertical center line of door and header:

Close door.

Measure door width at top.

Mark a point at center of door and on header directly

above door. Draw a center line to connect points.

Find Header Bracket mounting height (Figure 4):

(Do not attach Header Bracket).

. Raise door, watching top edge of door and stop door

when its edge reaches its highest point.

Measure distance ("H") from top edge of door to floor.

For sectional doors, add 2-1/2" to"H'[ Mark a point

on center line. Bottom of Header Bracket will be

installed here.

For one-piece doors, add 6" to"W: Mark this point on

center line. Bottom of Header Bracket will be

installed here.

NOTE

eFor both types of doors:

- If the ceiling in.your garage is so low that there is

not at least a 3 space above the Header Bracket

mountingpoint, contact a Genie Factory

AuthorizedDealer.

If a door spring is in the way, place the Header

Bracket avove the spring. Do Not move the door spring.

Check wall for a stud or a solid header at your mark:

(If checking a finished wall, a stud finder may be helpful).

If location is above Header, a 2" x 6" board must be

screwed to studs beside your mark with at least two Lag

Screws and Flat Washers (not provided).

Transfer your mark to new mounting board.

SECTIONAL DOOR

H + 21/2

H

ONE-PIECE DOOR

H+6"

Figure 4 Find Highest Point of Travel

11/=', llI'

Check ceiling or space above where Opener Power Head will be

mounted (Figure 5):

A Measure from garage door center line mark toward rear

of ga rage:

. Approximately 10' back if garage has a 7' 6" door.

Approximately ] 1' back if garage has an 8' O" door.

Approximately ] 3' back if garage has an 10' O"door.

Approximately ] 4' back if garage has an 12' O"door.

NOTE

Mounting Straps are included to attach the Opener to most

garage ceilings. Garage construction varies widely.

Additional mounting straps or angle iron may be needed for

your installation.

El Find location of ceiling joist or truss above where Opener

Power Head will be and estimate type and quantity of

materials needed for your installation (Figure 6).

120 Volt grounded outlet

or wiring box within 3 feet of

Power Head.

10'_

for 7-1/2' doors

__ ]]'__-

for 8' doors

-;oo4]]L!-

Figure 5 Check Power Head location

OPEN BEAM CEILING EXAMPLES

Mounting Straps Support board added

for longer spans

Perforated

Angle Iron

_(Angle iron not included)

FINISHED CEILINGS

Locate ceiling joists or

trusses using

a stud finder

or similar

device.

Attach angle iron

(not included) to

joists or trusses

through finish material

using Lag Screws.

Figure 6 Mounting methods for open beam and finished ceilings

CHECK ..... _ " ...... C[F L s_G FOB C_BOUH©E©

t>ow@:_Sou_:_cz

ACheck that there is a 15 Amp 120 Volt grounded electrical

outlet or grounded permanent wiring box (per building code)

within 3' of Opener Power Head:

If not, an outlet or wiring box must be installed. Contact

a licensed electrician for installation.

If building codes require permanent wiring, Power Head

must be partially disassembled to install appropriate

wiring in place of Power Cord. See page 19

NOTE

Permanent wiring must be installed by a Licensed

Electrician. Not all Genie Factory Authorized Dealers are

Licensed Electricians. Contact someone who is a Licensed

Electrician.

g%_ i,/s i,i i ii_ ,;

Check for wood garage frame, jamb, or masonry at mounting location

(6" above floor) with attachment tabs facing away from garage door

(Figure 7).

AIf you cannot mount Safe-T-Beam @Mounting Bracket to

wood frame:

.Concrete screws and concrete anchors (not included)

must be used to mount Brackets on masonry with

attachment tabs facing away from garage door.

.Safe-T-Beam @Mounting Bracket Extensions may be used

(not included - available from a Genie Factory Authorized

Dealer or through Accessories Order Form on pages 31/32).

_ _60_5 M I]IUb EbTOOLS

A

B

Tools (Figure 8):

Additional tools to make installation easier:

Slotted and phillips screw-driver bits

Stud finder

Sheet-metal cutting snips

Source I

Sensor

Safe T Beam @ ,i,l,,ll/ll_

Mounting Bracket

; // I _" Bracket 6"

#,_ I above

_ 41_r7 I floor

Figure 7 Mounting Safe-T-Beam @Components

IillT;40vE EXI_;_ll_G 6ABA_[I£

Check that the garage door locks, rope, and T-Handles are removed

from the garage door before starting the installation.

AIf your garage does not have a separate entry door, it is highly

recommended to install a Genie Emergency Release Kit (GER-2).

Emergency Release Kit lets you open garage door from outside if

there is a power failure. (Please see Accessories Order Form on

pages 31/32.)

Befo_,4_-9o __9f_x_t_"_e_,9<_t a_,_yterns a_,'_dtoo

_,s®®d®do 7'os_

[] Safe-T-Beam @Sensor Mounting Bracket Extensions (dealer)

[] Garage door opener reinforcement bracket (dealer)

[] Garage door frame reinforcement brackets, screws, bracing

or reinforcement kits (dealer)

[] Lag Screws (11/4") for a wood door less than 2" thick (store)

[] Electrical outlet and/or wiring (supplied by a

licensed electrician)

[] Excelerator Extension Kit (for 8' garage doors) (store)

[] Sufficient angle iron or strapping for hanging Power Head

(store)

[] Two 60Watt light bulbs

(Rough service bulbs recommended)(store)

[] GER-2 Emergency Release Kit for entry during power failure

(store)

[] Wood for header, ceiling, and/or door bracing reinforcement

(if needed)

[] Masonry fasteners for Safe-T-Beam @Bracket installation,

(if needed)

[] Masonry drill bit (if needed)

Drill

1/16" 5/32"

Drill Bit Drill Bit

6' or 7'

Step Ladde_

Adjustable Wrench

Phillips Screwdriver

Hack Saw

12' *

Tape

Hammer

Wire

Stripper

Safety Glasses

(1i¢ ">

Pencil

888888

1/4" 5/16" 3/8" 7/16" 1/2" 9/16"

Sockets

Carpenter's Level

Figure 8 Recommended Tools

item Part Name Quantity

Required

1 Power Head Assembly (main carton) 1 1

2 1/#L20 X 13/16" Hex Head Shoulder Bolt(blue bag) 2 2

(yellow bolt)

3 Rail Assembly (1 piece)(packagedseparately) 1

4 Rail Assembly (3 piece)(main carton) 1

4A First RailSection 1

4B Middle RailSection 1

4C End RailSection 1

8 1/#'-20 Hex Serrated FlangeNut (blue bag) 4 4

g RailClamps(blue bag) 4

10 5/16"-18 x 11/16 t_ Hex HeadShoulder Bolt (blue bag) 8

11 5/16"-18 Hex Serrated FlangeNut (blue & orange bags) varieS/mode 12

12 Magnetic Carriage Assembly (main carton) 1 1

13 Collar (blue bag) 3

14 Retaining Clip (blue bag) 3

15 RailStrap(blue bag) 1 1

16 1/4'L20 Hex HeadBolt (blue bag) 2 2

18 Open Limit Switch Assembly (Wbite)(green bag) 1 1

19 CloseLimit Switch Assembly (Brown) (green bag) 1 1

21 No. 8-32 x 1" Hex HeadScrew(green bag) 2 2

22 Emergency ReleaseCord (green bag) 1 1

23 Emergency ReleaseCord (Iong)(yellow) ld&lZon[y

24 Emergency ReleaseKnob (green bag) 1 1

25 Emergency ReleaseTag(green bag) 1 1

26 Header Bracket(orange bag) 1 1

28 Door Bracket(orange bag) 1 1

30 1/#' x 2" Lag Screw(orange bag) varieS/modeI 8

31 Straight Door Arm (main carton) 1 1

32 ClevisPin,3/8" x 15/16" (yellow bag) 2 2

33 Cotter Pin,.073_'dia.(yellow bag) 2 2

34 Curved Door Arm (main carton) 1 1

35 3/8_'x 7/8" Hex Head Bolt (yellow bag) 2 2

36 3/8 _'Hex Serrated Flange Nut (yellow bag) 2 2

37_ 2-Conductor Wire (main carton) 1 Roll 1 Roll

38_ Insulated Staple (red bag) approx.30 approx.30

40< Wall Console (main carton) 1 1

4Y #6 x 1-1/4" PanHead Screw (red bag) 2 2

42_ Entrapment Warning Label (manual)(main carton) 1 1

43_ Safe-T-Beam(STB)Sensor (GreenLED)(maincarton) 1 1

44_ Safe-T-Beam(STB)Source (Red LED)(maincarton) 1 1

45_ Safe-T-Beam(STB)Bracket (yellow bag) 2 2

46 Coupler (blue bag) 1 1

47_ NoJ 0 xl 1/4" Phillips HexHeadScrew(yellow bag) 4 4

48_ 1 Button Remote Control (main carton) /aAeS/mode

49_ 3 Button Remote Control (main carton) /arieS/mode

5@ Wireless Keypad(main carton) varieS/modeI aries/mode

51x 2 Button Remote Control (main carton) varieS/modeI /aries/mode

52_ Safety & Maintenance Guide (manua!(main carton) 1 1

53 WireClip (green bag) 7

54 Bumper (blue bag) 1 1

55x 5/16'L18x 3/4" HexHead Bolt(orange bag) 3

56 1/4-20 x 3/4" Self-drilling Screw(orange bag) 3 3

57 Mounting Straps(main carton) 2 2

' Denotesitems not shownon page8. Theseitemswill be illustrated

throughout the manualasrequired.

J4:_,,:_IW}BLJEXP_,.O©I}© Vll!r<

[11

(__ Model Number

item

1A

1B

1C

1D

1E

1G

1H

1K

1L

1M

1P

Part Name

Lens

Top Plate Assembly

Light Socket (2)

Motor Assembly

Cover

Motor Drive Board

Controller Board

No. 10-24 x 3/8" Hex Head

No.8-32 x r' Phillips Screw

No.8-32 x 3/8"Slotted Hex Head Screw

Power Cord

F:o_"Help _:sll ]-g00-35 61:11_411o viii wwwge_ai_r(ompal{y _.om 7

NOTE

Opener will not function unless Safe-T-Beam®System is installed and Force Controls are properly set.

One-Piece Rail Assembly (Genie Pro only) for 10' or 12' door includes:

Special"Close"Limit Switch with IongerWires.

96" Emergency Release Cord (yellow).

Rail Support Kit.

Rail Assembly (1 piece)

zz

@

ATurn Power Head upside down and place on a flat

level surface.

B Install Bumper (Figure 9).

CInstall Coupler on Motor Shaft (Figure 9).

CAUTION

The Drive Screw and Rail Liner can slide out of Rail Sections.

Keep Rail Sections level until the Opener is fully assembled.

D Connect first Rail Section to Opener Power Head. Connect

with 2 (1/4"-20) (yellow) Hex Head Shoulder Bolts and

2 (1/4"-20) Hex Serrated Flange Nuts (Figure 10).

Finger-tighten until later.

If you have a 1-piece rail unit, skip Assembly Step 2.

AArrange arrows on Rail Sections to point in same direction

and away from Power Head:

Push Middle Drive Screw out about 2" toward Power Head.

Slide Collar over Middle Drive Screw Hook (Figure 11A).

Turn Middle Screw by hand to align Drive Screw Hooks

between First and Middle Rail Sections.

. Latch two Hooks together and slide Collar over them

(Figure 11 B) and (Figure 11 C).

Snap Clip on Drive Screw next to Collar (Figure11D).

B Attach Middle Rail Section to First Rail Section, using 2 Rail

Clamps,4 (5/16"-18) Hex Shoulder Bolts, and 4 (5/16"-18) Hex

Head Serrated Flange Nuts onto Bolts (Figure 11).

Finger-tighten until later. (Middle Rail Section looks the

same on both ends. See page 8.)

C Attach End Rail Section to Middle Rail Section following

procedures in step A & B.

RailStrap

RailClamps

©

Coupler

First Rail

Section

5/16"-18HexHeadShoulderBolts

@)

_Q_Q_88_

5/16"-18HexSerratedFlangeNuts

88

1/4"-20Hex 1/4"-20HexHead 1/4"-20Hex

SerratedFlangeNuts ShoulderBolts HeadBolts

(yellow)

Bumper Collars+ spare RetainingClips + spare

Hardware (blue bag)

Bumper

(remove backing)

e%-"i

Coupler Power Head

Assembly

(i)

Figure 9 Install Bumper, Coupler and 1st Rail Section

Figure 10 Bolt ] st Rail Section to Power Head

NOTE

If the Extension Assembly (GSXL8) is needed, attach

it per instructions supplied with kit,

Retaining_"-.

\_ \\ \

Middle Rail ", _ Collar

Section @ f-.

Arrowspointtowarddoor

@ RailClamps

11A. Slipon collar

11B. EngageHooks

11C._Slide CollaroverHooks

11D._Snap on RetainingClip

Figure 11 Attach Middle Rail Section

_;:o__H_g:; _:s 1 800 3_.6_:B t: o vet 9

A

B

_S EMBtY Oh_TO _;_. tS

Place Magnetic Carriage Assembly Lever in "release" position.

Slide Magnetic Carriage Assembly into slot on End Rail

Section with arrow pointing away from the Power Head

(Figure 12).

Magnetic Carriage Release

Toward door

and header

Toward Power Head End Rail Section

©

Figure 12 Slide Magnetic Carriage onto Rail

A:T'T CH I:IAIL <->s TO I;I_ _'s

I:IAIL < = ......o>I_,. I ION

AAttach Rail Strap to End Rail Section with 2 (1/4"-20) Hex

Head Bolts and 2 (1/4"-20) Serrated Flange Hex Nuts

(Figure 13).

B Tighten snugly but Do Not over-tighten.

Rail Strap@ _ (_1_

I_ I < I''° p, Ii+ <" 14LI °H I:I?AIL ,2,E,,. I l;J ,=,=, I_HIi)

TI(IIITEH =LL _OLYS

AAlign all Rail Sections so Magnetic Carriage Assembly can

slide freely along length of Rail.

BSecurely tighten all fasteners now. Do Not over-tighten.

IIIST ILL IIIU© COb, IF,!ECT LB/ilT

o>@II,.HEo=

i!iiii! IiilBiI!i!iiI!i!iiI!i!iiI!i!iiI!i!i

A

B

C

D

Turn Opener right side up and support Power Head to avoid

damaging the Light Bulb Sockets.

Uncoil Limit Switch Wires and retain Twist Ties.

Place Switches on Rail with arrows pointing away from

Power Head (Figure 14).

Place Close Limit Switch (Brown Wire) 15" from Rail Strap.

Insert (#8-32 x 1") Hex Head Screw into Switch hole and

finger-tighten until later.

Place Open Limit Switch (White Wire) 15" from Power Head.

Insert (#8-32 x 1") Hex Head Screw into Switch hole and

finger-tighten until later.

Figure 13 Attach Rail Strap

White

Wire

Wire

#8-32

Hex Head Screws Wire Clips

Close Limit Emergency Emergency

Switch Assembly Release Knob Release Tag

Hardware (green bag)

Close Limit

Switch

(Brown wire)

Open Limit

Switch _--

(White wire)

@Wire

Clip

@

,_rrows point

:rdd

#8-32 x 1 //_

Hex Head_-_

Screws _lp

Figure 14 Install Limit Switches on Assembled Rail

NOTE

Loosen (Do Not Remove) Terminal Block Screws°

Limit Switch adjustments and securing the Wires

will be done later.

FLay Wires in channel on top of Rail and secure with Wire Clips

(Figure 14).

GCoil and bundle excess Limit Switch Wires on top of Power

Head with Twist Ties. Leave just enough Wire to reach

Terminals on back of Power Head (Figure 14).

14 Turn Opener upside down, and connect Limit Switch Wires to

Power Head Terminal Block (Figure 15):

*Terminal 4: OPEN Limit Switch Wire (white).

. Terminal 5: OPEN Limit Switch Wire (white) and

CLOSE Limit Switch Wire (brown).

.Terminal 6: CLOSE Limit Switch Wire (brown).

Antenna

J

/

Terminal White Limit Brown Limit

Block Switch wires Switch wires

Figure 15 Connect Limit Switch Wires to Power

Head Terminal Block

_'_ %1C: 11 "2 // . '/"

l<&l<l =_ !I W

ATie overhand knot at one end of Emergency Release Cord.

B Thread opposite end of Cord through Knob and hole in

Magnetic Carriage Assembly Release Lever (Figure 16).

C Tie overhand knot at this end of Emergency Release Cord.

D Attach Emergency ReleaseTag to Magnetic Carriage

Assembly Release Lever.

I:II!COBD I% _i:_, :> _ # '+ _#I_:: ,_El @OIsl!L

Al*'_![) S£BIAL l%h =_:+_'_>

I I 1,)_IY111, Z: II

Please note the following information so it is available if you need

to call us:

Date purchased: / /

Serial number (Figure 17):

Model number (Figure 17):

Dealer Name:

Dealer Address:

City:

State:

Zip:

Phone:

Emergency

'_--_ Release Knob

®

Figure 16 Attach Emergency ReleaseCord/Knob

and Tag

Model

Number

NOTE

Please keep original or photocopy of your sales receipt with

this manual for future reference should service ever be

required.

Serial

Number

(example)

WK YR PI

01 02 4E

Figure 17 Model and Serial Numbers

6ARA6E: DOOR ORHER _HS_kLAdT OH

NOTE

For lightweight garage doors, make sure you have installed

the proper reinforcement (SeeCheck Door Condition and

Thickness on page 3).

CAUTION

The Header Bracket must be fastened to the garage

framing. Do Not fasten the Header Bracket to drywall,

particle board, plaster, or other such material.

It may be necessary to attach a 2" x 6" board across the

wall studs above the door header to serve as a

mounting plate for the Header Bracket. The Bracket can

then be mounted at the proper location and have

sufficient support.

If a door spring is in the way, place the Header Bracket

above the spring. Do Not move the door spring.

Mount directly

into header

Use of Header Bracket

support board

Alternative Header Bracket orientations

Highest Point of door travel _

+ 2-1/2" (sectional door) or

+ 6" (one-piece door)

Figure 18 Attach Header Bracket above Garage Door

AIf needed, attach a 2" x 6" board (Figure 18) (also see page 4)

with at least two (four is recommended) Lag Screws and Flat

Washers (not supplied).

B Attach Header Bracket to header at mark above door.

NOTE

Mounting variations are shown in Figure 18. Any of these

may be used depending on space. However, it is critical that

the point where the Rail attaches to the Header Bracket be

on the center line of the door.

Mark 3 hole positions.

Drill 3 (5/32") pilot holes.

. Attach Header Bracket with 3 (1/4" x 2") Lag Screws.

Header

Bracket

®???

5/16-18 x 3/4"

Hex Head Bolts

1/4" x 2"

Lag Screws

Door Bracket

@®@®®

5/16-18 x 3/4"

Hex Serrated Flange Nuts

@7I??

1/4"-20 x 3/4"

Self-Drilling Screws

Hardware (orange bag)

CAUTION

Doors made of masonite, lightweight wood, fiberglass, metal,

or other lightweight materials must be properly braced

before mounting door Opener.

_o s; c o_Idoos

A

B

Place Door Bracket on door center line, no lower than top

roller, and mark holes (Figure 19).

Attach Door Bracket:

For metal doors, use 3 (1/4"-2O x 3/4") Self-Drtling

Screws (provided).

.For wood doors, use 3 (1/4" x 2") Lag Screws or

3 (1/4" x 11/4") Lag Screws (not provided).

or@

--_ @

SECTIONAL DOORS

Line of door

ONE-PIECE DOORS

Optional Door Operator Bracket (not included)

Figure 19 Attach Door Bracket

NOTE

Before installing, check length of the included Lag Screws vs.

the thickness of your garage door. For doors thinner than 2,

use 11/4 Lag Screws. Check door condition and thickness.

See page 3.

Fo o_-_e-piec_;> doo s::

APosition Door Bracket on door's center line, as high as

possible or on top of door.

B Attach Door Bracket:

.Formetaldoors, use3(1/4"-2Ox3/4")Self-Drtling

Screws.

For wood doors, use 3 (1/4" x 2") Lag Screws.

SS]I'TtIC/4 I;IAIL 0 MEIsIi)EI

AWhile supporting the Power Head, place threaded end of Rail

Strap Bolt through Header Bracket hole (Figure 20).

B Attach (5/16"-18) Flange Nut to Rail Strap Bolt.

Finger-tighten until later.

Rail Strap Bolt

Rail (_)

Header Bracket

Figure 20 Attach Rail Strap to Header Bracket

A Raiseandsupport Opener Power Head (along door center

line) higher than highest point of door travel (using step

ladder, etc.) (Figure 21).

B Measure distance from Opener to garage ceiling.

CAUTION

Mounting Brackets must be fastened to garage framing.

Do Not fasten to drywall, particle board, plaster, or other

such materials.

NOTE

Make sure the rail of your supported Power Head is

slightly higher than the highest point of door travel

by raisingthe door to check. Adjust asneeded.

Materials needed for mounting Opener Power Head

to garage may vary. Read all instructions completely.

Garage constructions differ. Extra material may be

needed. SeeCheckPower HeadMounting Areaon

page S.

SECTIONAL DOORS

Rail Should be level or dip down slightly.

Check for clearance.

CInstall Mounting Straps and/or support brackets (angle iron

not included) to joists or trusses and to mounting slots in

Opener. Use (5/16"-18 x 3/4") Hex Head Bolt, (5/16"-18)

Serrated Flanged Nut, and (1/4" x 2") Lag Screws as needed

(Figure 22).

DSecurely tighten all fasteners now. Do Not over-tighten.

ONE-PIECE DOORS

Set clearance at 1"-11/2" between Rail and door at

highest point of travel.

Figure 21 Checking Power Head position

OPEN BEAM CEILING EXAMPLES

Mounting Straps Support board added

for longer spans Perforated

Angle Iron

(Angle iron not included)

FINISHED CEILINGS

Locate ceiling joists or

trusses using

a stud finder

or similar

device.

Attach angle iron

(not included) to

joists or trusses

through finish material

using Lag Screws.

Figure 22 Mounting methods for open beam and finished ceilings

DOOBAB_4S

AAttach Curved Door Arm to Door Bracket with Clevis Pin and

Cotter Pin (Figure 23).

B Attach Straight Door Arm to Magnetic Carriage Assembly.

CAttach both Arms together with 2 (3/8" x 7/8") Hex Head

Bolts and 2 (3/8") Serrated Flange Hex Serial Number

Nuts so overall length is as short as pos-

sible. Securely tighten fasteners.

D Adjust height of Emergency Release Cord Knob to 6' above

floor:

.Pull Cord through Magnetic Carriage Assembly Lever

until Knob is 6' from floor.

Tie a new overhand knot in Cord at Magnetic Carriage

Assembly Lever.

A Attach Straight Arm to Door Bracket with Clevis Pin and

Cotter Pin (Figure 24).

B Attach Curved Arm to Magnetic Carriage Assembly.

C Attach both Arms together with 2 (3/8" x 7/8") Hex Head

Bolts and 2 (3/8") Serrated Flange Hex Nuts so overall length

is as long as possible. Securely tighten fasteners.

D Adjust height of Emergency Release Cord Knob to 6' above

floor:

.Pull Cord through Magnetic Carriage Assembly Lever

until Knob is 6' from floor.

*Tie a new overhand knot in Cord at Magnetic Carriage

Assembly Lever.

WARNING

Do Not skip Step D above!

Failure to comply may leave Emergency Release Knob within

reach of children. If the Knob is pulled with garage door fully

or partially open, garage door may close without warning!

A I

Clevis Pins Cotter Pins

Safe-T-Beam ® (STB) Brackets

#10-16 x 11/4"

Phillips Hex Head Screw

3/8" x 7/8"

Hex Head Bolts

3/8" Hex Serrated

Flange Nuts

Hardware (yellow bag)

As short as

_ossible

ht

-Curved

(_ Door Arm

Figure 23 Assemble Arms (SECTIONAL)

As long as

possible

Arm

Figure 24 Assemble Arms (ONE-PIECE)

ELECTRICAL WARNING

Ensure there is No power to the Opener before installing

Safe-T-Beam® System Wires. If Opener is plugged into outlet,

Unplug it now.

NOTE

The Opener will not close the door automatically unless the

Safe-T-Beam® System is installed.

A Install Safe-T-Beam @Source and Sensor (Figure 25):

,Mark both sides of garage door frame or wall 6"

above floor.

Hold Bracket against door frame or wall.Check if Bracket

extends out from wall far enough so tongue of Bracket is

beyond door, tracks, or any door hardware. If not, Safe-T-

Beam @Mounting Bracket Extensions are available from a

Genie Factory Authorized Dealer or through the

Accessories Order Form.

Blocks of wood, etc. may be substituted

for extensions.

Position top of Mounting Bracket at 6" mark and fasten

with 2 (#10-16 x 1-1/4") Phillips Hex Head Screws

per Bracket.

NOTE

Mounting Brackets can be attached to brick walls or concrete

floor using masonry anchors (not included).

B Attach Safe-T-Beam @Source (Red LED) and Sensor (Green

LED) to Brackets (Figure 25):

For single-door garages.

Determine which side of garage receives the most

direct sunlight, and place Source (Red LED) on this

side whenever possible.

,For multiple-door garages see (Figure 26).

Preventing crossed signals is critical.

Place Source and Sensor modules on adjacent doors

facing in opposite directions.

NOTE

To help prevent interference from the sun,the Safe-T-Beam®

Sensor (Green LED) may be placed further away from the

door opening, where it will spend more time in the shadows.

Slide the Safe-T-Beam @Source and Sensor onto the

tongues of the Brackets until they click into place.

Check final height of Lens (Figure 27).

Safe-T-Beam @Sensor

(Green LED)

®

Safe-T-Beam @Source

(Red LED)

Slide onto ,/_-___

tongue of

Bracket until/_;._ /

it clicks into _k_2)_' "'_ _

)' ,/ J _,, Bracket6"

place 7T J@ _ [ T°p°f

4 J I above

I f,oor

Figure 25 Install Safe-T-Beams @

GARAGE

TWO DOOR

GARAGE

THREE DOOR

GARAGE

Figure 26 Source/sensor Locations

_k

_i L _ "_i _ ,

Figure 27 Final Check Safe-T-Beams @

Top edge of Lens

5"- 6" above floor

CAUTION

_tapleswhich are too tight may cut or pinch Wires. Cut or

)inched Wires can cause the Safe-T-Beam® System to stop

vorking. When installing the Insulated Staples, make sure

_oufasten them only as tightly as needed to hold the

Wire securely.

1 1

CInstall Safe-T-Beam ® Wiring (Figure 28):

.Route Wire and Insulated Staples

(Figure 29 and Figure 30).

Securely fasten Wires with Insulated Staples as

you go. Staples should be snug only.

Wires between garage wall and Power Head should

be run on top of Rail and underneath Wire Clips.

Attach Wires to Safe-T-Beam ®Sensors.

Split and strip Wire ends to be connected as shown.

Loosen Terminal Screws.

Insert each Wire under flat plate and tighten Screw.

It does not matter which Wire, white or striped, goes

on which Terminal.

Attach Wires at Power Head.

Wires are connected toTerminals #2 and #3 on

Power Head Terminal Block. it does not matter which

Wire, white or striped, goes on which Terminal.

Check the following.

Ensure that no part of door or its hardware is in path

between Source or Sensor Lenses.

Ensure that tops of Lenses are between 5" - 6" above

floor. Brackets are flexible and can be adjusted slightly

if needed.

®

Insulated Staples

(approximately 30 parts)

Wi re

@

©

#6-11/4"

Pan Head Screws

Hardware (red bag)

P

approx.

1/2

Figure 28 Wire the Safe-T-Beam ® System

Wire Clips @

Insulated

Staples

NOTE

®

The Safe-T-Beam alignment check will be performed

following connection to electrical power.

Do Not plug in yet!

at Safe-T-Beam ® Leave slack for

adjustment

Terminal

attachments

at Power Head

Figure 29 Wiring Method A

Wire Clips (_

Insulated

Staples

®

Terminal

attachments

at Power Head

Figure 30 Wiring Method A

Leave slack for

adjustment

WARNING

Verify there is no power to the Opener before installing Wall

Console Wires.

NOTE

More than one lighted Wall Control per Opener will cause

a malfunction.

AWall Console (Figure :31):

Has a Security Vacation Lock Switch which disables

all controls.

LED Indicator shows whether system is powered, locked,

or unlocked. Makes Console easy to find in dark.

Controls door Opener from inside garage.

Independent Light Control allows convenient manual

control of Opener Lighting System.

B Find a convenient mounting location:

Within direct sight of garage door.

At least 5' above floor (to prevent small children from

operating garage door).

Away from any moving garage door or Opener parts (you

should not be able to reach door while standing at

Wall Console).

C Ensure Vacation Lock Switch is in UNLOCKED position.

D Wire Wall Console to Opener (Figure :32):

On Power Head, connect Striped Wire to Terminal #1 and

White Wire to Terminal #2.

On back of Wall Console, connect Striped Wire to

terminal "B" and White Wire to Terminal "W'[

EAttach Wall Console onto wall at location found above with 2

(#6 x ] 1/4") Pan Head Screws.

F Remove protective backing from Entrapment Warning Label,

and attach it to wall near Wall Console.

CAUTION

oUse of any wall consoles other than the type included

will prevent the light from working properly and could

cause the door to operate on its own.

Cut or pinched Wires can cause the Wall Console to stop

working. When using the Insulated Staples, be sure to

only tap them in as far as needed to hold the

Wire snugly.

Security

Vacation

Lock Switch

Independent

Light Control ]

©

Wall Console

@

Figure :31 Wall Console

®®®

Terminal

Attachment

at Power Head

White Wire

to

Terminal 2

Stri ped Wire

to

Terminal 1

Terminal

Attachment

at Wall Console

White Wire

to

Terminal "W"

Stri ped Wire

to

Terminal'B"

®

_qarage Door

/" Control

Allow

slack

Figure 32 Install Wall Console with

Entrapment Warning Label

ELECTRICALWARNING

e

A

To reduce the risk of electrical shock, this equipment has

a grounding type Plug that has a third (grounding) Pin.

This Plug will only fitinto a grounding type outlet. If the

Plug does not fit into the outlet, contact a qualified

electrician to install the proper outlet. Do Not change

the Plug in any way.The door Opener must be properly

grounded to prevent personal injury and damage to the

components.

The electrical power to the door Opener Must Be removed

when the Motor Cover is removed. Electrical power must

remain off while making electrical connections.

Check building codes:

If building code requires Opener be permanently wired

to building, have a licensed electrician perform step B.

If you are not installing permanent wiring, go to step C.

Instructions for licensed electrician - connecting power

with permanent wiring (Figure 33):

Remove power from circuit.

Remove Motor Cover.

Remove and discard Power Cord.

- Cut off Power Cord inside Power Head as near Strain

Relief as possible.

- Remove Knock-Out Plug, Strain Relief, and Power

Cord. (Cut Ground Wire on line side of Toroid).

- Dispose of Plug, Strain Relief, and Power Cord.

.Install required entrance bushing.

.Connect permanent wiring to Power Head Wires.

- White supply line to Opener White Wire.

- Black supply line to Opener Black Wire.

- Ground to Opener Green Wire.

- Replace Motor Cover.

NOTE

Use only Underwriters Laboratories, Inc. (U.L.)

recognized wire nuts.

The Circuit Boards are light sensitive. Ensure the

Motor Cover is installed before energizing

the Opener.

Knockout

Cut

Wires

here

Two

tabs

slide

Figure 33 Connecting power with permanent wiring

D

-Restore Power to circuit.

Connecting Power with Plug:

.Plug Opener into a grounded outlet as stated in previous

electrical warning.

Perform Safe-T-Beam ®alignment check:

.Check if Safe-T-Beam ®Source Red LED is glowing

continuously (OK) or blinking (problem).

If Red LED is blinking twice, adjust Sensor Brackets as

needed to make Red LED glow continuously. (Refer to

page 26.)

SIKL£II[ _" "'¢ < s_,,_'_

$,*W 11+= "

1 _>B,.f COITI( LS

Se, n_ofLm $_t(hes

ASetting Close Limit Switch (Figure 34):

Check that Magnetic Carriage Assembly is disengaged.

,With garage door fully closed, slide Close Limit Switch

until it is aligned with Carriage Assembly Magnet.

Tighten Set Screw. Do Not over-tighten.

B Setting Open Limit Switch:

,Manually open garage door to full open position.

Slide Open Limit Switch until it is aligned with Carriage

Assembly Magnet.

=Tighten Set Screw. Do not over-tighten.

Re-engage Magnetic Carriage Assembly.

NOTE

Little effort is required to turn the Force

Adjusting Knobs.

If the door stops moving while opening or

closing, adjust the Open Force or Close Force

Controls slightly clockwise (to sightly

increase the force) and retry the step.

The Open Force and Close Force Controls are to

be set to the minimum force necessary to

ensure the door smoothly opens fully and

closes completely.

The garage door will move slowly the first

time it runs, until the Opener'leams"the

type of door.

Ensure the Magnetic Carriage Assembly is

engaged and is between the two Limit

Switches before operating the Opener.

WARNING

The garage door opens rapidly, and can cause serious

injury or death.

Keep the path clean

Position the ladder to the side of the Power Head so it is

clear of all moving parts of the Opener and the door.

Set the door Opener to use the minimum force needed

to open the door.

APre-set Force Controls to midpoint between fully counter

clockwise and fully clockwise (Figure 35).

B Adjust the Close Limit Switch:

,Press Wall Console to close garage door.

If door does not close completely, measure distance

from bottom of door to floor. Move Limit Switch

same amount toward door and try again.

If door reverses after contacting floor, move Limit

Switch toward Power Head and try again.

If door reverses before contacting floor, increase

Close force and try again.

If door fails to move, check Safe-T-Beam ® System. See

Safe-T-Beam ®Troubleshooting Guide on pg. 26, and

Opener System Self-diagnostic Troubleshooting

on pg.27.

Tighten Limit Switch Set Screw. Do not over-tighten

(strip) Limit Switch Set Screw.

C Adjust Open Limit Switch:

, Press Wall Console to open garage door.

If door does not open completely, move Limit Switch

toward Power Head.

If door opens completely, but motor continues to

run, move Limit Switch toward door.

. Tighten Limit Switch Set Screw. Do not over-tighten

(strip) Limit Switch Set Screw.

Close Limit Switch

(door fully closed)

L: o,o_

Carriage _,_ Switch

(disengaged) _%_ Magnet

Open Limit Switch Switch

Carriage

(disengaged) I_ \_ .. "_

_ _) " Mag net

Figure 34 Setting Limit Switches

Force Controls

/

HI LO 0

OPEN CLOSE

FORCE FORCE

Figure 35 Making Force Adjustments

NOTE

eTo protect your new investment, your Excelerator®is

equipped with a Timer and Cycle Counter which work

together to prevent any chance of heat damage to

electrical circuits caused by too many cycles in too short

a time. If your Opener suddenly stops responding to the

Wall Console - Do Not Unplug the Unit - simply wait

10 minutes for the Timer/Cycle Counter to reset itself

and try again.

Unplugging the unit will prevent theTimer/Cycle

Counter from resetting.

D Test Door Opener:

Run door up and down a few times using Wall Console

and observe door travel.

.Repeat steps above as needed to set Limit

Switch positions.

E Adjust Open Force to minimum needed:

.Place door in closed position using Wall Console.

.Gently adjust Open Force fully counterclockwise

(minimum force).

.Run Opener using Wall Console.

.Observe that door runs to Open Limit Switch.

- If not, adjust Open Force Control slightly clockwise,

close garage door, and open it again.

Repeat steps above until garage door runs smoothly

from Close Limit Switch to Open Limit Switch.

FAdjust Close Force to minimum needed:

Place door in open position using Wall Console.

.Gently adjust Close Force fully counterclockwise

(minimum force).

Run Opener using Wall Console.

Observe that door runs to Close Limit Switch.

- If not, adjust Close Force Control slightly clockwise,

open garage door, and close it again.

Repeat steps above until garage door runs smoothly

from Open Limit Switch to Close Limit Switch.

NOTE

Limit Switch and Force Adjustments must be completed

before checking the contact reverse function (Figure 36).

AOpen garage door using Wall Console.

B Lay a 2" x 4" board flat in center of doorway.

C Close door using Wall Console.

D Check that door stops and reverses within 2 seconds after it

contacts board:

If door does not reverse, decrease Close Force until

door reverses.

If door still does not reverse, move Limit Switch

toward door.

E Check Safe-T-Beam ® System operation:

If beam is blocked, door will not close.

NOTE

The door must contact the 2" x 4" board before the

Carriage activates the Close Limit Switch. If not,

readjust the Close Limit Switch.

2" x 4" board

laid flat

Figure 36 Checking Contact Reverse

t+}F/0 6 _:/f%_tilP?}H6 T4_

_:_I_/_OT_

ATo program one Button of a Remote Control (Figure 37):

Locate Learn Button and Learn Indicator Light near

Terminal Block on Power Head (Figure :38).

. Press and release Learn Button. Red Learn Indicator Light

will blink 2 times per second.

Press Remote Control Button once within 30 seconds.

Red Learn Indicator Light will stay lit.

. Press Remote Control Button again. Red Learn Indicator

Light will go out, indicating that memory is stored.

B Program each additional Remote using step A above.

Yo D_se £II Bet;isotes fl_ols_s Rowe Head Is4_Jsi}oty

APress and hold Learn Button on Power Head for 10 seconds or

until Learn Indicator Light goes out. Memory is erased:

. Program Remotes again as needed.

'R} F:lep/a e l:&Iemote Co_t_'o/Batte y

A Push in on Battery Cover Latch at base of Remote Control

(Figure 39):

. Use coin, pen, screwdriver or any similar device.

Cover snaps open.

.Replace old Battery with new _EVEREADV. A23,

12 Volt Battery.

B Snap Battery Cover closed.

WARNING

A moving garage door may cause serious injury or death.

Keep people clear of opening while door is moving.

Do not allow children to play with the Remote Controls.

If the Safety Reverse does not work properly:

Close the door and disconnect the Opener using the

Emergency ReleaseCord.

Do not use the door Opener, Remote Controls, or

Wireless Keypad.

Refer to the door and door Opener Owner's Manuals

before attempting any repairs.

A Press Button on Remote Control. Garage door will move.

B Press Button again. Garage door will stop:

The door automatically stops at the end of the open or

close cycle.

CPress Button again. Garage door will reverse.

NOTE

Each Remote Control must be programmed

separately.

The Remote Controls will not cause the door

Opener to close the garage door if the Safe-T-

Beam® System is malfunctioning.

When programmin_ the Remote Controls, they

must be at least 24 from the Antenna Wire.

If the red Learn Indicator Light blinks

approximately 4 times per second,

programming has stopped. If programming

has stopped, repeat the above steps.

Each Button on a 2 or 3 Button Remote Control

is for a different Opener. You cannot use more

than one Button per Remote, per Opener.

A maximum of seven Remote Controls or

Wireless Keypads can be stored into the

Receiver at one time. If a Remote Control

becomes lost, or if you want to delete a Remote

Control or Wireless Keypad, see "To EraseAll

Receiver Memory."

1 Button 2 Button

Remote Remote

® ©

Figure 37 Genie Remote Controls

3 Button

Remote

@

Learn Code Button

Figure 38 Learn Code Button and Indicator Light

Visor Clip

Push to open

Battery Cover

Model

Number

Figure 39 Remote Control Battery Replacement

sn6%'_

AWARNING

A Moving door can cause serious injury or death,

1 Keep people clear of opening while door is moving.

2 Do Not allow children to play with Wireless Keypad.

3 During programming, the door opener could begin

to run, so stay away trom the moving door and its

parts.To keep the door from moving, close the door

and disconnect it from the Openerby pulling the

Emergency Release.

if Safety Reverse does not work properly

1 Close door and disconnect the Opener using

Emergency ReleaseCord.

2Do not use door Opener, Remote Controls, or

Wireless Keypad.

3 Refer to Door and Door Opener Owner's Manuals

before attempting any repairs.

NOTE

FOR CONVENIENCE-- Program Keypad BEFOREmounting.

A Set Wireless Keypad PiN (Personal ID Number):

Activate programming mode.

Press (in order) @@@

Red LEDblinks - once per second.

• Enter your PIN (3to 8 characters).

• Press

Red LEDblinks - twice per second and turns off.

Programming One Door Operator: Figure 1

Find the Learn Code Button and Learn Code

Indicator LEDon your door opener.

Ifyour door opener hasa black antenna

wire,the Learn Code Button and Indicator

LEDare located near the antenna.

(The light lens may need to be opened)

Ifyour door opener doesnot have an

antenna, you have an external receiver.

The external receiver cover must be

removed to accessthe Learn Code

Button and Indicator LED.

Pressthe Learn Code Button.

LearnCode Indicator LED(on Opener)

will blink.

Enteryour PINand press _.

Learn Code Indicator LEDstayson.

• Press_ again.

Learn Code Indicator LEDturns off.

Indicator

Learn l.-

Code_

Button

Operating One Door Operator:

To move the garage door:

Enteryour PIN.

Press_j_,.

NOTE

®

®

®

If the door does not move, check the red LEDon

Keypad. If the LEDis blinking rapidly,the PINwas

entered incorrectly. After the LEDstops blinking,

re-enter your PINand try again.

Any keypad button will control the door for

30 seconds after the door starts moving.

Rapid Blinking of the red LEDindicates an error.

After afew seconds the LEDwill turn off. Start over.

?_,xceec to"Mew t _'g W _ less H_y sa_:....

P eg_a_f_<s's _sgf®_ 2 O_ 3 DOH Ope_";@_s

A Set Wireless Keypad PIN (Personal ID Number):

Activate programming mode.

- Press (in order)

- Red LEDblinks-once per second.

Enteryour PIN(3 to 8 characters).

• Press

- Red LEDblinks - twice per second and turns off.

B Programming the Keypad for Multiple Door openers:

Enteryour PINand press

- Red LEDblinks- once per second.

Press_ again.

- Red LEDblinks - twice per second.

Pressthe number of doors (total) you wish

tocontrol (@ or @).

• Press

- Red LEDblinks several times and turns off.

C Programming Door Openers:

Decide which door will be door #1,#2 and #3.

Pressthe Learn Code Button (see Figure 1).

- Learn Code Indicator LED(on Opener) blinks.

Enteryour PINand press _7_.._

_.

-Learn Code Indicator LEDstays on.

Pressthe number you have picked for this

door Opener ( @ or @ or @).

- Learn Code Indicator LEDstays on.

" Press _- _}_

- Learn Code Indicator LEDturns off.

B Repeat step A above for each door opener.

Eachdoor opener must be programmed to receive the

signal from the Wireless Keypad.

R_og_'ammi_ g Fog' 2 o_"3 _",i)0o_'Ope_se_s (ConUnued)

AOperating 2 or 3 Door Openers:

To move one of the doors.

Enteryour PIN.

®

®Press door opener number ( @ or @ or @ ).

588 ;:_ E s_ ]OF * OF F*BEVOUS COLU_H

NIOUHTIH6 IHS'FI:IUC[]OH5

AMount Keypad.(Mounting screws located inside

battery compartment.)

Remove Battery Cover. See Figure 3.

Drilla 1/1d'pilot hole for the top mounting screw.

Install a screw into the drilled hole,

leaving a 1/8" gap between the

screw head and the wall.

See Figure 2.

Hook the Keypad over the screw.

Mark,drill pilot hole and fasten

bottom screw.

Reinstall Battery Cover.

Figure 2

scre&ap

Figure 3

Red LED

Bottom

_/ Mounting

Screw

Presshere _,-_'_ ]

x_====:d

AEnteryourPIN

• Press

B EntertheTemporary PIN(from3 to 8 characters).

Press b

NOTE

. DO NOT reprogram the Door Opener(s).

.Temporary PIN remains active until the next time your

normal PIN is entered.

l!b. Ill] ADDKIO='d_ L i '6TBIJ ,KI IA'6 [d _ [ =If {I II<_ ==11 (It=,

AEraseold PIN:

Press and hold in order ___},.(_ .

- Red LEDwill blinkonce and turn off.

Release all buttons.

B Programming Door Opener(s).

Return to"Programmin_ for 1Door Opener"or

"Programming for 2 or 3 Door Openers."

Snap Lens Hinges into

slots on back of Motor Cover

60 Watts

_--_---_ maximum Push in

Lens _ Latches

@ to

close Lens

Figure 41 Install Lens Cover and Light Bulbs

AInstall two 60Watt light bulbs (not included) into Light

Sockets (Figure 41):

* Rough service, ] 30 Volt bulbs are recommended.

B Install Lens into slots in Motor Cover.

C Install Genie Emergency Release Kit (GER-2) accessory,

if purchased.

Installation is now complete.

D

f

Transmitters comply with all United States and Canadian legal requirements

asof the date of manufacture. No warranty is made that they comply with all

legal requirements of any otherjurisdiction.lf transmitters are to be used in

another country, the importer must determine compliance with any local

laws and regulations which may differ from United States and Canadian

requirements prior to use.

Los transmisores cumplen con todas lasreglamentaciones legales de los

Estados Unidos y del Canada, en la fecha de fabricaci6n. Ninguna garantia

se da que cumpian con todas as reglamentaciones legales de ninguna otra

jufisdiccibn. Silos transmisores sevan a utilizar en otro pals, el importador

debe determinar sicumplen con lasreglamentadones y leyeslocales que

puedan ser diferentes alas reglamentaciones de los Estados Unidos y del

Canada,antes de usar los mismos.

Les _metteurs sont conformes _ la r_glementation am_ricaine et canadienne

compter de leur date de fabrication. Aucune garantie n'est stipul_e

indiquant qu'ils sont conformes _ toutes les prescriptions ]uridiques d'autres

autorit_s. Si les _metteurs sont utilis_s dans d'autres pays, il incombe

l'importateur d'en d_terminer bur conformit_ aux lois et r_gles locales

pouvant diff_rer de cellesdes _tats-Unis et du Canada avant toute

utilisation desdits _metteurs.

Sendeger_te entsprechen allen gesetzlichen Bestimmungen in den USA und

Kanada zum Zeitpunkt der Herstellung.Wir Obernehmen keine

Gew_hrleistung for die [inhaltung aller gesetzlichen Bestimmungen in

anderen L_ndern. Sollen Sendeger_te in anderen L_ndern eingesetzt werden,

so muss der Importeur vor dem Gebrauch sicherstellen, dass die Sendeger_te

auch sokhen [okalen Bestimmungen entsprechen, welche von den

Bestimmungen der USAund Kanadasabweichen.

x@a}_lOll _xl nI_[ 9_L}E_-_°-4 _--_-A_j_l__ EF_XI_---e-bC[Xt_°l

A Monthly:

Door springs and door hardware:

- Oil door roller, bearings, and hinges using silicone

lubricant or light oil.

WARNING

Do not operate door automatically or manually if springs

are broken. Contact a Genie Factory Authorized Dealer for

service or call Customer Service at 1-800-3S-GENIE.

Balance Door.

Closedoor.

Release Magnetic Carriage Assembly from Rail Assembly

by pulling down on Emergency Release Knob.

Raise door manually 3'- 4' and verify that door stays at

that position. SeeCheck Step 2 on page 3.

NOTE

When the door is 3'- 4' above the ground, the door

should stay open. Slight movement is acceptable. If

the door moves too much, contact a Genie Factory

Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

Reattach Magnetic Carriage Assembly to Rail Assembly:

a. Pull the Emergency ReleaseKnob toward Power Head.

b. Close door.

Contact ReverseTest.

Perform Installation Step 10 on page 21.

WARNING

If the door fails to reverse on contact with the board,

adjust the Close ForceControl as specified in Set Limit

Switches and Force Controls on page 20. Ifthe Opener

still fails, contact a Genie Factory Authorized Dealer for

service or call Customer Service at 1-800-35-GENIE.

B Yearly:

+ Wipe off old excess lubricant from Drive Screw.

+ Lubricate Drive Screw with Genie Lubricant (GLU-3)

NOTE

Use ONLY Genie Lubricant (GLU-3). Other lubricants

may damage the Opener.

GLU-3

Lubricant

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCCRules.

Operation is subject to the following two conditions: (1)

this device may not cause harmful interference, and (2)

this device must accept any interference received, includ-

ing interference that may cause undesired operation.

WARNING

TO REDUCE THE RiSK OF SEVERE iNJURY OR DEATH

1 READAND FOLLOW ALL INSTRUCTIONS.

2Never let children operate or play with the Door Controls. Keep the Remote Control away from children.

3 Always keep the moving door in sight and away from people and objects until the door is completely closed.

NO ONE SHOULD CROSSTHE PATHOF THE MOVING DOOR.

4 NEVERGO UNDER A STOPPED,PARTIALLYOPEN DOOR.

5 Test Opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat)

at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door

Opener. Failure to adjust the Opener properly may cause severe injury or death.

6When possible use the Emergency Release only when the door is closed. Use caution when using this Release

with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing

the risk of severe injury or death.

7 KEEPGARAGE DOORS PROPERLYBALANCED. See Owner's Manual. An improperly balanced door increases the

risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring

assemblies, and other hardware.

8SAVETHESE INSTRUCTIONS.

, WARNING

Usethe Wall Console included with Opener. Any other wall console can cause the Opener to operate unexpectedly and

the light to stop working.

TI%, yUBLEJHO,, y GUIDE

Source (Red LED)

ON

OFF

OFF

2 BLINKS, Pause

(Repeat)

2 BLINKS, Pause

(Repeat)

3BLINKS, Pause

(Repeat)

4BLINKS, Pause

(Repeat)

Sensor (Green LED)

_z_z

ON

OFF

ON

ON

OFF

,J

ON

ON

Possible Problem

Normal operation

Power Head not powered

Wiring from Power Head bad

Wiring to Source missing or bad

Beam not aligned

Beam obstructed

Sensor defective

Wire to Sensor missing or bad

Sensor defective

Sensor receiving interference

Source not sending pulses

Source defective

Solution

None required

Check breakers, fuses,plugs

Checkwiring for obvious shorts

Check wiring

• Check Source, Sensor alignment

Check for obstruction

Contact Customer Service

Check wiring

Contact Customer Service

Determine source of interference

Contact Customer Service

• Contact Customer Service

• Contact Customer Service

See Status Light on Figure38, page 22)

You See

1 BLINK,

Pause

(Repeat)

2 BLINKS,

Pause

(Repeat)

3BLINKS,

Pause

(Repeat)

4 BLINKS,

Pause

(Repeat)

5BLINKS,

Pause

6BLINKS,

Pause

7 BLINKS,

Pause

8BLINKS,

Pause

Problem

Motor Drive

Boa rd

Normal

operation

restored

If the problem

recurs

Operation not

restored

Controller

Boa rd

Interrupt

Opener

Overheated

or

Force Settings

Incorrect

Safe-T-Beam ®

Malfunction

Wall Console

does not work

Limit Switches

not working

Wall Console

locked

What to Do

Reset Opener--unplug (or disconnect power), wait 5 seconds, plug

back in (reapply power), and activate from Wall Console.

First Cycle will run at slow speed.

automatic garage door balance detection system. An improperly

balanced door, damaged or worn counter-balance spring, binding

door hardware or rollers may result in a "ONE-BLINK" signal.

Contact Customer Service for further assistance.

Check door condition.

Have a Genie Factory Authorized Dealer check:

- Fuse on Motor Drive Board.

- Ribbon Cable on Motor Drive Board is properly inserted into

Connector on Controller Board.

Reset Opener- unplug (or disconnect power), wait 5 seconds, plug

back in (reapply power), and activate from Wall Console.

Have a Genie Factory Authorized Dealer check that Ribbon Cable on

Motor Board is properly inserted into connector on Controller Board.

Do not unplug or disconnect power from Opener. Wait 10 minutes

for internal clock to provide additional cycles. Cycles are restored

at a rate of S cycles per 10 minutes of rest.

Check Force Settings. NOTE: Force Settings are not pre-set at factory.

Check door condition.

Check Safe-T-Beam ® Self-diagnostk System. NOTE: Safe-T-Beam ®

System must be installed and operational to enable door to close.

Check Wall Console Wiring for shorts, tight Staples, or pinched Wires.

Check Wiring Connections at Power Head and Wall Console.

Check Limit Switch Wire connections to Terminals on Power Head.

Check for shorted or pinched Wires under Limit Switch Brackets.

Vacation Locking Switch on Wall Control is in "Lock" mode.

Unlock switch.

NOTE

Reference

See Door

Safety Guide

1. See page 3.

2. See door

Safety Guide

1.See page 20.

2.See Door

Safety Guide_

See page 16.

See page 18.

See page 20.

See page 18

The status LED Indicator Light is located under the Lens Cover.The Green LED light will turn ON,then OFFwhen

power is applied to the Opener. If LED stays ON, have a Genie Factory Authorized Dealer check the Controller

Board, or call Customer Service at 1-800-35-GENIE.

®

If Safe-T-Beam problems exists, the door can be closed electrically by holding the Wall Console Button down

until door is fully closed.

The Remote Controls and Wireless Keypad will not work without a working Safe-T-Beam® System.

Problem What To Do

Opener does not run 1. Check power source.

from Remote Control A. If Opener is connected to an outlet:

Plug a working lamp into outlet used for Power Head.

. If lamp glows, power source and outlet are OK.

If not, check fuse or circuit breaker or non-compatible GFCI.

NOTE: A licensed electrician must replace non-compatible GFCI's.

B. If Opener is connected to a wiring box:

Check fuse is not blown, or circuit breaker is"CIosed"(not tripped).

If still no power, have a licensed electrician check circuit and wiring.

2. If power is OK:

Check connections at Power Head Terminals (seeWall Console Installation page 18), tightening any

loose connections.

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive

Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE.

Door Opener starts Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires).

for no apparent reason Replace any shorting Staples and shorted Wires.

WasRemote Control lost or stolen? If so, eraseall Remote Control codes from Receiver's memory

and reprogram for remaining remote controls. (See EraseAll Receiver Memory on page 22).

Door starts down, then . Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 20).

stops before it is Adjust as needed.

completely closed Checkfor shorted Wires.

Check aragedoor for binding

Door starts down, then . If a new installation, check Door Arm position.

stops and goes back up . Check operation of Contact Reversefunction.

. Check Safe-T-Beam6)System for beam obstruction or misalignment of Lenses.

Check Safe-T-Beam= System diagnostic code.

. Check CloseForceadjustment (seeSet Limit Switchesand ForceControls on page 20). Adjust as needed.

Check garage door for binding.

Door will only run closed Check Open Limit Switch for a short circuit and for proper wiring.

. Check Open Force adjustment (seeSet Limit Switches and ForceControls on page 20). Adjust asneeded.

Check condition of garage door and door spring(s).

/!5\;_' /_6: If you suspect a problem with the garage door hardware or springs,contact a Genie

FactoryAuthorized De aler for service, or contact Customer Service at 1-800-35-GENIE.

Door will only run open . Check Safe-T-Beam_ System asdetailed in the Safe-T-Beam6)System Self-diagnosticTroubleshooting Chart

(seeSafe-T-Beam_ SystemSelf-diagnosticTroubleshooting Section on page 26).

Check CloseLimit Switch for a short circuit and for proper wiring.

Check CloseForceadjustment (seeSet Limit Switchesand ForceControls on page 20). Adjust as needed.

Lights will not turn off . Disconnect Wires connecting WallConsole to Power Head (seeWall Console Installation on page 18).

Checktheir condition and either replaceor reconnect.

Until a replacement Wall Consolecan be obtained, disconnect Wall Consoleand use only Remote Controls

or WirelessKeypadto operate Opener.

Door starts up, but stops Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

before it is balanced as detailed in Maintenance Section.

completely open ,. STA_::_I_P,6: If you suspect a problem with the garage door hardware or springs, contact a Genie

Factory Authorized De aler for service, or contact Customer Serviceat 1-800-35-GENIE.

Check Open Limit Switch for a short circuit and for proper wiring.

Check Open Forceadjustment (seeSet Limit Switches and ForceControls on page 20). Adjust as needed.

Operator runs,but door . EnsureMagnetic CarriageAssembly is engaged to RailDrive Screw(seeInstall Magnetic Carriage Assembly

does not move onto Railson page 10).

oCheck Forceadjustment (seeSet Limit Switchesand ForceControls on page 20). Adjust as needed.

Checkthat all sectionsof RailDrive Screware turning when Motor runs. If not:

- Checkcondition (not cracked,split,or broken) and placement of Coupler. Replaceas needed.

- Checkcondition (not cracked,split,or broken) and placementofCollarandClip. Replacethem

as needed.

Wall ConsoleVacation EnsureMagnetic CarriageAssembly is in contact with Close Limit Switch.

Lockfunction does Checkwhen door isfully closed,that Carriageactivates CloseLimit Switch. If not,adjust position of Close

not work Limit Switch (Seepage 19).

_ R Is "i S}O 35 6IN _: st vs}; www !s}_<!' e<:os<Iat_7,+';oIs'

What To DoProblem

Remote Control has less

than 25' operating range

Opener works from Wall

Control, but not from

Remote Control

Noisy operation

Safe-T-Beam®System

Door closes,and Opener

shuts clown

.Relocate Remote Control inside car.

.Ensure Remote Control is pointing toward garage door when pressing Control Button.

Replace Remote Control Battery _EVB?EAD_ type"A23." (See page 22).

Reposition Opener Antenna Wire.

Do Not attem t to retune Remote Controls or Receiver

Program code for each Remote Control into Receiver memory (SeeProgramming the Remote

Control on page 22.

.Replace Remote Control Battery _EIfB?EAD_ type"A23." (See page 22).

Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.

Check Safe-T-Beam®System for any diagnostic codes. If present, troubleshoot as detailed in

Safe-T-Beam®System Self-Diagnostic Troubleshooting Chart (Seepage 26).

Ensure all fasteners are tightened.

Check that the garage door and Opener are in good repair, properly lubricated, and properly

balanced. (SeeMaintenance page 25).

If you suspect a problem with garage door hardware or springs, contact a Genie

Factory Authorized Dealer for s rvice,orcontact Customer Serviceat 1-800-35-GENIE

If an operational problem exists, Opener will not run closed.

Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.

Check Safe-T-Beam®Systemfor any diagnostic codes. If present,troubleshoot asdetailed in Safe-T-Beam®

SystemSelf-DiagnosticTroubleshooting Chart (Seepage 26).

Check position of Wall ConsoleVacationLockSwitch. It must be in UNLOCKEDposition for Opener to

open door.

WALL CONTROL

m

_u

i-

o3

WHITE

1 WHITE __

i OPEN LIMIT z

Opening Cover May Cause Electric Shock [

CONTROLLER BOARD

-@

®

-@

J_

-@

PRIMARYGROUND

MOTOR DRIVE BOARD

GREEN

l LiNE

PLUG

I 9 BLUE

I 8 BLACK

WHITE

6WHITE

5

_o

MOTOR

GREEN _1_

SECONDARYGROUND

What sC_veed

Any defect in material and workmanship from personal, normal

household use in accordance with the Owner's Manual.

HSOOODSeries -- Lifetime _ on motor, on parts and service,

ISDggO Series -- Lifetime _ on motor, I years _ on parts.

ISDggO-2 Series -- Lifetime _ on motor and all parts.

ISDgg5 Series -- Lifetime _ on motor and all parts.

ISDggS-2WKM Series -- Lifetime _ on motor and all parts.

ISDI000 Series -- Lifetime _ on motor, all parts and service.

CMD9900 Series -- Lifetime _ on motor, 5 years _ on parts.

PRO99 Series -- Lifetime _ on motor and all parts.

for as long as you own your home.This warranty is non-transferable.

This warranty applies only to the consumer who originally purchased

the product.

This warranty applies only to Genie products purchased in the United

States and Canada.

If your Genie product is defective, we will send replacement parts or, at

our option, a replacement unit at no charge to you, excluding shipping,

handling and labor costs. If we send replacement parts for your Genie

product, we may use new or reconditioned parts. If we choose to send

a replacement unit, we may use a new or reconditioned one of the

same or similar design.

IMPLIED WARRANTIES, INCLUDING THOSE OF FITNESS FOR A

PARTICULAR PURPOSE AND MERCHANTABILITY (AN UNWRITTEN

WARRANTY THATTHE PRODUCT IS FIT FOR ORDINARY USE) ARE

LIMITED TO ONE YEAR FROM DATE OF PURCHASE. GENIE WILL NOT PAY

FOR: LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY DAMAGE

CAUSED BYYOUR GENIE PRODUCT OR ITS FAILURE TO WORK; ANY

SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES; ANY DAMAGES

RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT.

Some states and provinces do not allow limitations on how long an

implied warranty lasts or the exclusion of incidental or consequential

damages, so the above exclusions and limitations may not apply.

This warranty is the only one we will give on your Genie product, and

it sets forth all our responsibilities regarding your Genie product.

There are no other expressed warranties.

State and Province Rights: This warranty gives you specific legal rights,

and you may also have other rights that vary from state to state and

province to province.

MOW 06et' ""_ , = 1= +' / ?_f]_

To get warranty service for your Genie product, you must

provide proof of date, and place of purchase of the product.

Call Genie Customer Service toll free at 1-800-354-3643, or visit

our website at www.geniecompany.com.Trained Genie

representatives will assist in diagnosing the problem and will

arrange to supply you with the required parts for do-it-yourself

repairs.Trained service representatives are available Monday -

Friday, 8:00 AM - 11:00 PM, and on Saturday, 11:00 AM - 8:00 PM

Eastern Time (subject to holidays).

You can obtain the name of a Genie Factory Authorized Dealer

by calling the Genie Dealer Locator Service at 1-800-654-3643.

If an Authorized dealer provides warranty service, Genie will not

reimburse you or otherwise be responsible for any labor

charges, Your choice of one of the above described service

options is your remedy under this warranty.

. Batteries (which are considered replacement parts)

. Installation

. Commercial use

. Defects resulting from accidents

. Damage while in transit to our service location or damage

from alterations

Misuse or Abuse

Lack of proper maintenance

Unauthorized repairs or modifications of the product

Affixing of any attachment not provided with the product

Programming of Remote Control Devices

Programming of Keypads

Safe-T-Beam _"_adjustment/cleaning

Staples through wiring

Pinched or broken wires

Carriage disengaged

Force Control adjustments

Door out of balance

Broken springs or cables

Power outages

Use of extension cords

Missing or damaged parts on discounted, clearanced, final

sale or taped cartons

. Phantom operations

. Fire

. Flood

. Acts of God

. Failure to follow the Owner's Manual

¢o®sse _®s _f;;,_eufeuw'e,_;;,ey'l;ed_og......_4_

(GIT-1)DeluxeRemoteControlwith Intellicode- Allowsremoteoperationof garagedoor

Controladorremotode lujo con Intellicode®-Proporci6naroperaci6nremotode lapuertadelgaraje

T_lecommandede luxe avecIntellicode-Permettreoperation@loign'deportede garage

(GIT-2)2-ButtonRemote Control with Intellicode®-Allowsremoteoperationof2 garagedoors

Controladorremotode 2 funcionesconIntellieode'- Proporci6naroperaci6nremotode doslaspuertasdelgaraje

T_l_commande_ 2 fonctionsavecIntellJcode_-Permettreoperationeloign'deuxportesde garage

(GIT-3)3-ButtonRemoteControlwith Intellicode®-Allowsremoteoperationof 3garagedoors

Controladorremotode 3 funcJonesconIntellieode®-Proporcidnaroperacidnremotode treslas puertasdelgaraje

Tel_eommande_ 3 fonctionsavecIntellJcode®-Permettreoperation61oign'troisporfesdegarage

(GPWC-2WLB)LightedWailConsole - OperatesGarageDoorIndependentlightcontrolSecurityvacationlock

Consolade paredde 3 funciones- Accionalapuertadelgaraje.Controldeluz independiente.Cerraduradeseguddadparavacaciones

Consolemurale_troisfonctions -Actionnelaportede garage.Commanded'edairageind@endanteInterrupteurdeverrouillagede s@urite

(GMI-3)3-ButtonMini RemoteControlwith Intellicode - Fitseasilyintopocketorpurse

Minicontroladorremotode 3 funeionesconIntellicode®-Cavefacilmenteen elbolsilloo cartera

Minit_l_commande_ 3 fonctJonsavecIntellieode' -seglissedanslapochede vestonou lesaca main

(GWKP)WirelessKeypadEntrySystem-OperatesInte@ode_GarageDoorOpenerswithoutRemoteControlorkey

Sistemade entradaportecladonum_ricoinalambrico-Accionalos abridoresde puertasde garajeIntellicode_sincontrolremotoo Ilave

a_5 Syst_med'ouvre-portede garage_claviersans fil- Actionnelesouvre-portedegarageavectnte]licode®sanst_l@ommandenicie

z

w (GLU-3)f/4 oz.TubesScrewDriveLubricant(3)- Ensuresproperequipmentwearprotection

LU

z 1/4onceLubricantede tornillo accionar(3)- Aseguracomponentecorrectoproteccidnpotdetefioro

_D Laonza1/4Lubricantde la vie (3)- Garantircomponantexactparsystcmedefenseversuser

_< (GWB)UniversalWall Button- Providesadditionalconvenientinsideoperationof door

_u Bot6nde pareduniversal- ProporcionaoperaciOnconvenientedela puertadesdeel interior

Boutonmuraluniversel- ActionneI'ouvre-portede rintCrieurdu garage

<

_:_: (GPS-5)PerfectStop®-Ensuresperfectparking

¢

_< Stop Perfecto- Aseguraelestacionamientoperfecto

®

ButoirPerfectStop - Permetde stationner8 laperfectiondartslegarage

O

I-

z (GSXL-8)ExceleratorScrewDriveExtensionKit- AneighteeninchExtensionto increasethetravelof a ScrewDriveOpenertoaccommodateaneightfootdoor

Elextensi6ndeslizantede ExceleratorScrewDrive- Unaextensionde18pulgadasparaaumentarlacarreradeunabridordeslizabbdetomilio,paraacomodarunapuertade8 pies(2,43m)

u_ N_cessairederallongedu ExceleratorScrewDrive- Rallongede 30dm(18pc)prolongeant ]a coursede I;ouvre-porteScrewDrivepouruneportede 2,4m (8pi)de hauteur

£3

<l:

u_ (GIRU-tT)UniversalConversionKit- ConvertsanyGarageDoorOpenerto asecureradiosignalsystemKit includesa RemoteControl,ReceiverandTransformer

z

','2 Juegodeconversi6nuniversal-Conviertecualquierabridordepcertadegarajea unsistemadeserialderadioseguro.Eljcegoinduyeuncontrolremotodeabridordepuertadegaraje,

_< receptory transformador

z Necessairedeconversion universel -Transformetoutouvre-portede garageensystcmedes@urit_a signalradioComprendunet_i@ommanded'ouvre-portedegarage,unr_cepteuret

untransformateur

o 60WATTEnhanced/RoughServiceLight Bulb- Ensuresproperequipmentcompatability

z

< Bombillade 60Vatios- Aseguracomponentecorrectodesistema

_: Eelairagede 60WATT-Garantircomponantexactparsysteme

u_ (GER-2)EmergencyReleaseKit- Providesaccessto garagefromoutsideintheeventof anelectricalpowerfailure

zJuegodepica-portede pestillo- Permitirentrtadadesdepotfuerade garajeporquecortedeel@trice

N_cessairesde D_clenchementde secours- Le necessairede d@lenchementdesecoursestconpupourvouspermettred'acc_dera votregaragedepuisIext¢rieurencasde pannede

_- courantet Iorsqu'il

c_ STBAdapterBrackets(2)- UsedinconjunctionwithstandardSTBMountingBracketsTheyprovideadditionalclearancealongwithmountingoptions

z Eladaptadorponeentre par_ntesis(2)- Usadoen unionconpar_ntesisuniformesde montardeSTB,ellceproporcionanel espaciolibreadicionaljuntoconmortarlasopciones

o Crochetsd'adaptateur- UtiliseconjointementavecSTBstandardmonterlescrochets,!isfournissentledegagementsupplementaireavecmonterd'options

<

<

uJ

I- No C.OD shipments Please include check or money

order, made payable to The Genie Company Do not

send cash. Allow 3-4 weeks for delivery. We accept

Visa or Mastercard on phone orders only

1-800-354-3643 Please have part number and credit

card ready

Please add local sales tax if you reside in one of

the states listed.

California indiana

Connecticut Maryland

Florida Massachusetts

Georgia New Jersey

Illinois New York

TOTAL ORDER

SHIPPING & HANDLING

STATE SALES TAX

GRAND TOTAL

Ohio

Tennessee

Virginia

Wisconsin

Michigan

$

$ 500

$

$

No se aceptan pedidosde pago contra entrega (COD).

Sirvase inc]uir su cheque o giro postal, la cuenta

pagadera hecha a The Genie Company. No envie

dinero en efectivo Concedanos3 a 4 semanas parala

entrega. Aceptamos pedidos telef6nicos de Visa o

Mastercard.1-800-354-3643.Sirvaeetener listos los

nQmerosdel modelo y de la tarjeta de credito.

Sirvaee agregar el impuesto de ventas local si usted

reside en uric de Ice siguientes estados:

California Indiana

Connecticut Maryland

Florida Massachusetts

Georgia New Jersey

illinois New York

TOTAL DEL PEDIDO

FLETE Y MANEJO

IMPUESTO DE VENTAS ESTATAL

GRAN TOTAL

Ohio

Tennessee

Virginia

Wisconsin

Michigan

$

$ 580

$

$

Isst_'uct o_'ssCommssds_t

Pasd'expeditioncontreremboarsement.Veai]lezinclureun

chequeou un mandatbancaire,le payablefaira TheGenie

Company. N'envoyez pas d'argent comptant. Accordezde 3

4 semainespourta livraison. Nousacceptons lescommandes

partel@honeavecpaiementpar cartede creditVisaou

Mastercard1-880-354-3643.Ayezsouela mainlenumerodela

pieceet celuide lacartedecredit

Veuillez indiquer lee taxesde ventelocales eivous r_sidez

dane I'un des _tats r_pertori_s ci-dessous.

Californie Indiana Ohio

Connecticut Maryland Tennessee

Floride Massachusetts Virginie

Georgie New Jersey Wisconsin

Illinois New York Michigan

COMMANDE TOTALE $

MANUTENTION ET EXPEDITION $ 508

TAXE DE VENTE $

TOTAL GLOBAL $

Prices on Reverse Los Precios en otro lado Les Prix sur I'autre cote

GEI IE

3-ButtonRemoteControlwith Inte!/code®

Contrdadorremotede 3 funcionescon Intelicode_'

TelGcommandea 3 fonctionsavecIntellicode_'

MODEL DESCRIPTION

MODELO DESCRIPCION

MODELE DESCRIPTION

DeluxeRemoteControlwith Intellcode®

GIT-I Contreladerremotode lujo con Inte!/code®

Tel@ommandede Bxe avec Intelicode®

2-ButtonRemoteControlwith Inte!/code_

GIT-2 Controladerremotode 2 funcionescon inteilicode_">

Tel@ommandea 2 fonctionsavecIntellicode®

GIT-3

LightedWa/Console

GPWC-2WLBConsolade paredencender

3-ButtonMiniRemoteControlwith Intelicode<_'

Minicontroladorremotode 3 funciones

GMI-3 conIntelicode_'

Minitel@ommandea 3 fonctonsavecIntelicodd_

GWKP

GLU-3

WirelessKeypadEntrySystem

Sistemade entradaper tecladonum@icoinalambrico

Systemed'ouvre-portede garage£ claviersansfil

PRODUCTCODE

CODIGO

CODEDUPRODUIT

1/4oz,TubeScrewDriveLubricant(x 3)

1/4onceLubricantede torn/Io accionar(x 3)

Laonza 1/4Lubrifiantde lavis (x 3)

UniversalWail Button(unlit)

Bot6nde pareduniversal(unlit)

Boutonmuraluniversel(unlit)

PerfectStop_'

StopPerfecto_"

ButoirPerfectStop_'

PRICE(US$)*_iQTY,

PREClO* iCANTIDAD

PRIX($US)* iQTE

33069R $34.95

33069S $44.95

33069T

34292R

34909R

35282R

34965R

34960R GWB

GPS-5 34964R

GSXL-8 33523S

$49.95

$13.95

$39.95

$49.95

TOTAL

TOTAL

TOTAL

$t .95

$4.95

$4.95

$34.95

611"-1

GIT=3

ScrewDriveExtensionKit(For Excelerator)

Elextensi6nde cadenadesfzable(ParaExceJerator)

N@essairede prolongement

ducoulsseau(PourExcelerator)

i-I

GPWC-2WLB

GWKP

LU-3

GWB @

GPS-5

GSXLo M

UniversalConversionKit

GIRU-IT Juegodeconversi6nuniversal 33154R

Necessairede conversionuniversel

60WattEnhanced/RoughServiceLightBulb

LIGHTBULB Bombilade 60Vatios 26210A,S

Edakagede 60Watt

EmergencyReleaseKit

Juegode pica-portede pestilo 34963R

N@essairesde d'clenchementde secours

GER-2

ADAPTER

BRACKET

$49.95

...........................

$2.95

$29.95

STBAdapterBrackets(2)

Eladaptadorponeentrepar@tesis(2) 34439R.S $4.95

Crochetsd'adaptateur(2)

G,RU-,T

LIGHT BULB

GER-2

8TB BRACKET

EXTEN81ON8

LUl

sj

_z!

21

sj

uJl

Zl

©I

<I

wl

_d

C31

S

zl

<I

zl

wl

<I

wl

zl

c31

ol

<I

* Prices subject to change without notice

* Valoran el cambio con sujecidn a sin nota

* Les prix assujettissent pour changer sans ta notification

@t " s/1"4 , I:11'

;:N V/tP/i/l::t _ I'll w!e

NAME/NOMBRE/NOM

ADDRESS/DIREC@ON/ADRESSE

CITY/QUDAD/VILLE STATE/ESTADO/ETAT ZIP/CODIGO POSTAL/CODEPOSTAL

I/IAiloOHDL£R OR/F "O:

_ic Rc ,.,. ,'0,:, c .c _,-.RR,..,, cv_:;_ A:

The Genie Company

22790 Lake Park Blvd.

Alliance, Ohio 44601-3498

Python 2 Garage Door Opener Track Extendion Kit

Source: https://usermanual.wiki/Genie/EXCELERATOR.877086655/html

0 Response to "Python 2 Garage Door Opener Track Extendion Kit"

Postar um comentário

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel